Limit Switch |
 |
As increasingly sophisticated flow control systems are
installed to improve productivity and reducemaintenance
downtime, stringent requirements are evolving within the
process industry for reliable monitoring and control
systems. |
| |
|
| |
Rotary and Linear Valve Position Monitors |
 |
Designed around a unique self-locking spring-loaded TouchSet cam mechanism attached
to a stainless steel shaft and housed in a weatherproof rated aluminium, stainless steel or engineered resin enclosure, the Accutrak utilised bushings at both ends to assure concentric
turning of the cams.
For digital signalling to lights,motors,micro processors or peripheral equipment, two
position sensors are standardly housed within the enclosure. The requirement for tools
to adjust cam settings is unnecessary.The self-locking TouchSet cam mechanism allows
for a quick and simple hand operation in the setting of both sensors. Additionally, the
Accutrak is specifically designed for ease of wiring by the incorporation of abundant
working space and a direct wire-feed terminal block. All that is necessary to make the
unit operational is the bringing in of electrical leads to a single juncture. |
| |
Control Monitors |
 |
Addressing the increasing demand for low power monitoring and control of automation
process valves, theWestlock Quantum LP integrates position sensors, low power energy
solenoid valves, and fugitive emissions monitors into a single unit meeting the specific
standards set by international approval agencies. Engineered and certified to meet
Weatherproof and HAZARDOUS location requirements and ATEX category 1, 2 or 3 areas,
the Quantum LP elevates the integration of sensors and controls to a new level. |
| |
Network Monitors |
 |
By integrating an I/O card within the Quantum Control Monitor, Westlock has created the
capability for networking field devices.The merging of field devices and I/O results in the
elimination of remote I/O cabinents, reduction of wiring costs, and efficient on-line predictive
and maintenance diagnostic programs.
Network Protocol include As-i,Devilenet,Modbus, Profibus and Foundation Fieldbus. |
| |
|
|
|